Fiberglass
Lamp Changer Poles
Designed for commercial use, these TeleScoping Lamp Changer Poles are
designed to be used by qualified personnel to change large wattage commercial
lamps in overhead light fixtures. Made with high-strength fiberglass,
a full size 35-foot pole weighs only 7 lbs. Poles extend and lock for use
at any length of segments extended.
Rubber covered fingers with garter springs on McGill lamp changers make
changing a variety of lamp types simple. Hard-to-reach lamps are easily
replaced without using ladders or platforms. A variety of styles and sizes
is available to fit practically all commonly used lamps. Models for use
with incandescent, mercury, metal halide, and sodium lamps.
-
Garter spring grips lamps firmly
-
Lightweight for ease-of-use and convenience
-
Insulated to help protect against shock
-
Changes lamps up to 35-ft height (poles sold separately)
Each pole must be used with any one of a variety of McGill Lamp
Changer heads for each type of commercial lamps.
Also available are poles designed for general purposes with a variety
of tip-end attachments. See Fiberglass TeleScoping
Poles.
Maximum length of pole manageable by an individual with good physical
strength is limited to 10 meters (~30 feet). This is due to the nature
of relative weight of the far end of the pole at distance. Beyond
10 meters is beyond the reasonable limits of an individual's personal strength
and ability to control the hook-end of the pole.
When a pole extended more than 10 meters (30 feet)* is to be used, it
is required to have the assistance of additional persons and use of counterweight
on pole base is recommended. |
.
See Warnings & Utilization Notes
and Pole Utilization Errata
Prices, Telopole-II,
Stealth
T-Lock™,
Measurement Sticks, Range
Poles, Tripod System, Retriever
Poles, Order
Lamp Changer Poles
| Full Length |
Segments |
wt. |
Collapsed
Length |
part no. |
Price (US$) |
| 20 ft |
5 |
2.75 lbs |
59 inches |
L-20 |
220. |
| 35 ft
* |
8 |
7 lbs. |
64 inches |
L-35 |
450. |
. |
Select McGill Lamp Changer:
(Required w Lamp Changer Pole)
150-CA
15-100watt
us$85 |
151-CA
25-200watt
us$64 |
152-C
300-500watt
us$62 |
153-C
750-1500watt
us$77 |
163-C
50watt MercVapor
35-400watt
Sodium
70-175watt
MetalHalide
us$50 |
161-C
75-250watt
Mercury Vapor
50-1000watt
Sodium
175-400watt
MetalHalide
us$53 |
A-15, A-17, A-19,
G-16½, G-18½ |
A-19, A-21, A-23, P-25, PS-25, PS-30,
PS-35, G-25, G-30,
SL-18 |
PS-35, PS-40, G-40, G-48 |
PS-52, G-48, G-64 |
E-17, E-18, E-27
ED-17, ED-18, B-17 |
E-21, E-23, E-23½, E-25,
E-28, ED-23½, E-28, T-28 |
| Coil
Spring |
| 7013 |
7013 |
7014 |
7014 |
7013 |
7013 |
Select McGill Lamp Changer:
(Required w Lamp Changer Pole)
154-C
1000-1500watt
400-1000watt
Mercury Vapor
us$94 |
158-C
400-700watt
Mercury Vapor
400-1000watt
MetalHalide
us$134 |
154XL-C
1000watt
MetalHalide
us$139 |
156-C
50-500watt
100-500watt
Mercury Vapor
us$120 |
155-C
500-1000watt
Flood
400-750watt
Mercury Vapor
us$143 |
159-C
400watt
Mercury Vapor
Flood
us$177 |
| T-16,
T-18, T-20 |
E-37, BT-37, BT-46, ED-37 |
BT-56 |
R-30, R-40, PAR-30, PAR-36, PAR-38,
ER-30, ER-40 |
R-52, R-57 |
R-60 |
| Coil
Spring |
| 7013 |
7014 |
7014+7019 |
7014 |
7019 |
7019 |
.Order
Lamp Changer Accessories.
Broken Lamp Base Remover
200
us$33 |
Lamp Changer
Replacement
Coil Spring
7013 us$6
7014 us$7
7019 us$8 |
.
Storage Cases
| part no. |
Pole type |
Price (us$) |
| C-30 |
L-20 |
32. |
| C-35 |
L-35 |
35. |
. |
|
Images not to scale.
Subject to mfgr availability; prices subject to change.
All prices above for USA product in US$. Plus shipping
and applicable taxes, duties or tariffs.
OH resident's will be charged sales tax, recipients must
pay any other applicable taxes, duties or tariffs.
All sections are tested per OSHA, ASTM F-711, IEC-855
& IEC-1235. |
|
Pole Base Counterweights
10 Lb Set Weights
us$24.95 |
20 Lb Set Weights
us$49.95 |
|
.
Prices, Telopole-II,
Stealth
T-Lock™,
Measurement Sticks, Range
Poles, Tripod System, Retriever
Poles, Order
|
WARNING
|
Pole strength and durability are unknown. However,
manufacturer evaluations indicate impressive resistance to pole failure
with nominal loads in hook end. Poles are capable of being raised
and lowered from horizontal to vertical while fully extended, without danger
of pole failure or excessive bending.
See Utilization Notes above.
When a pole extended more than 30-feet (10 meters) is
to be used, it is required to have the assistance of additional persons
and use of counterweight on pole base is recommended. |
| DANGER |
Not recommended for use in the vicinity of electrical
power, power lines or any other potentially electrical environment
without proper additional safeguards, precautions and special personnel
safety training.
|
Manufactured by Hastings, Inc. and/or McGill Electrical Group,
Inc.
* Distributor & Manufacturers assume no personnel
liabilities what-so-ever in the use of these products.
End user assumes full responsibility for any hazards,
injury or deaths which may result from any proper or improper utilization
of these poles. |