NBC Systems
NBC main, Detectors, Protective Suits, Dosimeters

Gas Masks

Chemihood
Chemihood
Emergency Evacuation Hood
Promask 2000
Promask 2000
Full Facepiece Gas Mask
M95
M95
NBC Full Facepiece Gas Mask


Gas Masks, Filter Canisters, Blower, Prices/Order Form

Filter Canisters
CLICK to Enlarge.
.
M95 Full Spectrum Filter Canister
  -Long Acting Activated carbon
  -HEPA high efficiency filter
Protection Full spectrum ²
NATO std
Casing Reinforced polyamide
Breathing resistance <120 Pa (1.2mbar)
@30 l/min
Aerosol penetration rate <2.10 -5
Diameter 109mm
Height 90mm
Weight 320g
Threaded coupling 40mm EN148-1
Shelf Life 10 years
.
Cyanogen chloride 
Chloropicrin 30 lpm
Carbon tetrachloride
.
>40 min
>55 min
>50 min.
  Aerosol Penetration:
DOP at 30 lpm
Paraffin oil 95 lpm
NaCl 95 lpm
.
.
<0.0003%
<0.003%
<0.001%
.
sarin and other nerve gases, mustard gas, cyanogen, arsine, phosgene; radioactive and highly toxic particles; aerosols and micro-organisms; bacteria and viruses.  Industrial gases, organic gases and vapors, inorganic gases and vapors, chlorine, hydrogen cyanide, hydrogen sulfide, ammonia, methylamine, organic and inorganic acids, such as formic acid, sulfur dioxide, hydrogen fluoride, and hydrogen chloride
all filter canisters have no chromium
TLV=threshold limit value ACGIH & Biological Exposure Indices, 2000
IDLH=Immediately Dangerous Life/Health NIOSH guide to chemical hazards 1990.
All Specifications are subject to change or modification without advance notice.

Gas Masks, Filter Canisters, Blower, Prices/Order Form.
SafetyTech™
C420 Blower
for use with gas masks

provides positive pressure inside mask needed to support strenuous activity,
uses (2) filter canisters
Specifications

C420 Specifications
C420 Blower
(shown with Remote Cable Assembly and (2) canisters)
C420 Blower 3-Speed System:
M-60043-001 
Blower, 3-Speed (M-60010-001)
Breathing Tube Assy. w/ 90° Swivel  (S-30013-001)
Web Belt Assy.,  60" Lg x 2" Wide  (S-30019-001)
Airflow Indicator (AFI)  (S-30020-001)
Battery LiSO2, BA-5800/U  (M-20020-001)
C420 Blower Single-Speed System:
M-60033-001
Blower, Single-Speed Toggle  (M-60031-001)
Breathing Tube Assy. w/ 90° Swivel  (S-30013-001)
Web Belt Assy.,  60" Lg x 2" Wide  (S-30019-001)
Airflow Indicator (AFI)  (S-30020-001)
Battery, LiSO2, BA-5800/U  (M-20020-001)
Remote Cable Assembly (shown above)  (M-60039-001)
Molded Carrying Case (C420 system) 17 x 12 x 5½ inches  (C-10046-001)
Molded Carrying Case (Gas Mask & C420) 19 x 14 x 7¼ inches (S-10079-001)
.

Warranties apply to integrity of equipment and components as delivered to perform according to design specifications. 
Equipment requires special training for proper usage.  No warranty is implied for utilization of equipment by trained or untrained personnel. 

  NOTICE:  This is highly specialized equipment which requires training for proper use. 
Ensure all personnel expected to utilize equipment obtain training from qualified instructors (i.e., police, fire, military).
.



detectors

masks

suits

dosimeters
For Further Information, Email  or  Call 440-888-4749 (M-F 9-5 ET)
Order FormEmail
top of page
Home, Computers, Special Technologies, Company Info, Personnel, Clients & Projects, Contacts, E-mail
©2004 GeoData Systems Management Inc., Berea, OH 44017-0366 USA