NBC Systems
NBC main, Masks, Protective Suits, Dosimeters

AP2C Detector, TIMs Detector, APACC, Accessories, ORDER
Proengin, France
AP2C Chemical Warfare Agent Detector

US$18,200.
M266 E00 003
Export License & End User Restrictions Apply
.
The AP2C unit is a Chemical Warfare (CW) agent detector based on the flame photospectometer.  It detects nerve and mustard agents and identifies Vx in liquid and vapor forms.  Highly sensitive, it detects the presence of sarin at a concentration of 10 micrograms/m³ in 2 seconds.  Suitable for initial reconnaissance, the AP2C also provides unique capabilities for mass screening and monitoring decontamination on casualties and equipment.  The AP2C is constructed to military specifications and is fielded in military forces and civil defense agencies worldwide including France, Sweden, Israel and Australia, and with fire departments and federal agencies of the US government.

Available with various accessories and interfaces for expanded surveillance use, special applications, test modules and portable test bench.  Also available in versions for vehicular use and portable detection alarm systems.  Other equipment available for facilities and marine detection systems. 

The AP2Ce is a special version designed to be used in an EXPLOSIVE ATMOSPHERE.  Otherwise it has the same characteristics as the AP2C, except that it incorporates additional reheaters which reduce its battery autonomy and prevent it from being used below -10°C (-14°F).  M232 E00 003  US$21,100.

For remote CW agent detection monitoring, see APACC and APACC Kit for the AP2C.
 

Kit provides instant detection of chemical warfare agents in both vapor and liquid forms.  AP2C is engineered to detect traces of vapor or liquid contamination by nerve and mustard (G, V, HD) agents simultaneously in all operational and climate conditions, even if the agents are not chemically pure.  Easy and reliable to:
  • Monitor initial contamination and screening of casualties who may be contaminated.
  • Monitor residual contamination after decontamination of personnel anc casualties, equipment, infrastructure and ground.
  • Immediate detection of chemical contamination by flame spectrophotometry (sulphur & phosphorus atoms)
  • Simultaneous G, V, HD agent detection
Cycle time: 1 minute after a detection 
Sensitivity:  1.7.10-3  ppm Vx (17mg/m³)
1.7.10-3  ppm GB (10mg/m³)
1.7.10-3  ppm HD (400mg/m³)
Response Time: less than 2 seconds
Operation: £  2 minutes (T ³ 68º F)
Duration: 12 hours with battery unit & H2 storer

Unit Weight:  4.4 Lbs. (2 Kg)
Weight of S4PE (liquid detector): 0.9 Lbs. (.4 Kg)
Kit Weight:  13.2 Lbs. (6 Kg)
Kit Dimensions: 18.1 x 7.1 x 4.7 inches (460mm x 380mm x 170mm)
Storage Temperature:  -38.2°F to +160°F (-39°C to + 71°C)
Rain Proof  (model AP2Ce Intrinsically Safe)
Decontaminable body/interchangeable wedging
Shock proof, withstands being dropped from 39.37 in (1 m) high

Export License & End User Restrictions Apply

Click to Enlarge

AP2C Kit Contents:

(1) AP2C portable detection systems for gas and liquid agents
(1) S4PE device for sampling liquid agents
(2) Hydrogen storage devices
(2) SAFT Lithium Ion Batteries
(2) S4PE batteries
(1) pack of (10) sample scrapers
(1) pack of (10) test scrapers
(1) buzzer clip
(1) S4PE sampling tube
(1) spare sampling nozzle
(1) Technical Guide
(1) black Pelican Case for detector & hardware
.
AP2C
Symbol Name Chemical Name Chemical Formula Cas#
Vx Vx O-ethyl-S-(2-iisopropylaminoethyl) methylphosphonothiolate C11-H26-N-O2-P-S 50782-69-9
Ve Ve O-Ethyl-S-[2-(diethylamino)ethyl] ethylphosphonothioate C10-H24-N-O2-P-S 21738-25-0
Vg(Vm)  Amiton O,O-Diethyl-S-[2-(diethylamino)ethyl] phosphorothioate C10-H24-N-O3-P-S 78-53-5
GA Tabun Dimethylphosphoramidocyanidic acid, ethyl esthe C5-H11-N2-O2-P 71-81-6
GB Sarin Methylphosphofluoridic acid, 1-methylethyl ester C4-H10-F-O2-P 107-44-8
GD Soman Methylphosphonofluoric acid, 1,2,2-trimethylpropyl esther C7-H16-F-O2-P 96-64-0
GF Cyclosarin Cyclohexyl methylphosphonofluoridate C7-H14-F-O2-P 329-99-7
GE . Phosphonofluoridic acid, ethyl-, isopropyl ester C5-H12-F-O2-P 1189-87-3
HD Distilled Mustard Nearly pure Mustard C4-H8-Cl2-S 505-60-2
H Sulfur Mustard 2,2'-Dichlorodiethyl sulfide ( 20-30% Sulfur Impurities) C4-H8-Cl2-S 505-60-2
HT Sulfur Mustard 60% HD 40% T agent to lower freezing point C8-H16-Cl2-O-S2.
C4-H8-Cl2-S
172672-28-5
Not suitable for use to detect Toxic Industrial Materials, Gases & Vapors
(See TIMs Detector) 

NBC main, Masks, Protective Suits, Dosimeters
AP2C Detector, TIMs Detector, APACC, Accessories, ORDER
Proengin, France
Toxic Industrial Materials Detector (TIMs)
.
Detector is a flameproof portable equipment for industrial chemical contamination control. 
Does NOT detect Chemical Warfare (CW) agents.
Does not require End User License nor subject to Export Restrictions.

US$18,800.

TIMs
Engineered to detect vapor or aerosol Toxic Industrial Materials (TIMs) such as sulfides, chlorides and other industrial vapors and gases (see table).  TIMs does NOT detect Chemical Warfare agents and does not require End User Certification or Export Licenses. 
  • Suitable for use in rough conditions
  • Fast turn-on
  • Immediate identification and measurements
  • Single-handed operation
  • Immediate detection of chemical contamination by flame spectrophotometry (sulphur & phosphorus atoms)
  • Does NOT detect Chemical Warfare (CW) agents 
Cycle time: 1 minute after a detection
Sensitivity: 1.7.10-3  ppm  (400mg/m³)
Response Time: 2 seconds
Operation: £  2 minutes (T ³ 68º F)
Duration: 12 hours with battery unit & H2 storer

Unit Weight:  4.4 Lbs. (2 Kg)
Unit Dimensions: 15.15 x 3.38 x 5.43 inches (385mm x86mm x 138mm)
Kit Weight:  13.2 Lbs. (6 Kg)
Kit Dimensions: 18.1 x 7.1 x 4.7 inches (460mm x 380mm x 170mm)
Storage Temperature:  -25°F to 131°F (-32°C to + 55°C)
Rain Proof,  Intrinsically Safe
Decontaminable body/interchangeable wedging
Shock proof, withstands being dropped from 39.37 in (1 m) high

Export License and End User Certification not required

TIMs Kit Contents:
(1) TIMs portable detection systems for vapor & aerosol agents
(2) Hydrogen storage devices
(2) Rechargeable Batteries and 110v Charger, or 
(2) SAFT Lithium Ion Batteries
(1) yellow Pelican Case for detector & hardware 
(1) Technical Guide
TIMs(Open list)
Ammonia Phosphorus oxychloride
Arsine Phosphorus pentafluoride
Carbon disulfide Sulfur trioxide
Hydrogen sulfide Sulfuryl chloride
Phosphorus trichloride Arsenic trichloride
Sulfur dioxide Dimethyl sulfate
Sulfuric acid Ethyl phosphonothioic dichloride
Carbonyl sulfide Ethyl phophonic dichloride
Chlorosulfonic acid Parathion
Methanesulfonyl chloride Tetraethyl pyrophosphate
Phosphine H C N
Not suitable for use to detect Chemical Warfare Agents 
(See AP2C Chemical Warfare Agent Detector)
specifications subject to correction and modification
NBC main, Masks, Protective Suits, Dosimeters
AP2C Detector, TIMs Detector, APACC, Accessories, ORDER


detectors

masks

suits

dosimeters
For further information, Email  or Call 1-440-888-4749 (M-F 9-5 ET) 
EmailEmail
top of page
Home, Computers, Special Technologies, Company Info, Personnel, Clients & Projects, Contacts, E-mail
©2005 GeoData Systems Management Inc., Berea, OH 44017-0366 USA