AP2C Detector, TIMs Detector,
APACC,
Accessories,
ORDER
Proengin, France
AP2C Chemical Warfare Agent Detector |
US$18,200.
M266 E00
003
Export
License & End User Restrictions Apply |
.
The AP2C unit is a Chemical Warfare (CW) agent detector based on the
flame photospectometer. It detects nerve and mustard agents and identifies
Vx in liquid and vapor forms. Highly sensitive, it detects the presence
of sarin at a concentration of 10 micrograms/m³ in 2 seconds.
Suitable for initial reconnaissance, the AP2C also provides unique capabilities
for mass screening and monitoring decontamination on casualties and equipment.
The AP2C is constructed to military specifications and is fielded in military
forces and civil defense agencies worldwide including France, Sweden, Israel
and Australia, and with fire departments and federal agencies of the US
government.
Available with various accessories and interfaces for expanded surveillance
use, special applications, test modules and portable test bench.
Also available in versions for vehicular use and portable detection alarm
systems. Other equipment available for facilities and marine detection
systems.
The AP2Ce is a special version designed to be used in an EXPLOSIVE ATMOSPHERE.
Otherwise it has the same characteristics as the AP2C, except that it incorporates
additional reheaters which reduce its battery autonomy and prevent it from
being used below -10°C (-14°F). M232
E00 003 US$21,100.
For remote CW agent detection monitoring, see APACC
and APACC Kit for the AP2C.
|
Kit provides instant detection of chemical warfare agents in both vapor
and liquid forms. AP2C is engineered to detect traces of vapor or
liquid contamination by nerve and mustard (G, V, HD) agents simultaneously
in all operational and climate conditions, even if the agents are not chemically
pure. Easy and reliable to:
-
Monitor initial contamination and screening of casualties who may be contaminated.
-
Monitor residual contamination after decontamination of personnel anc casualties,
equipment, infrastructure and ground.
-
Immediate detection of chemical contamination by flame spectrophotometry
(sulphur & phosphorus atoms)
-
Simultaneous G, V, HD agent detection
Cycle time: 1 minute after a detection
| Sensitivity: |
1.7.10-3 ppm Vx (17mg/m³)
1.7.10-3 ppm GB (10mg/m³)
1.7.10-3 ppm HD (400mg/m³) |
Response Time: less than 2 seconds
Operation: £ 2 minutes (T ³
68º F)
Duration: 12 hours with battery unit & H2 storer
Unit Weight: 4.4 Lbs. (2 Kg)
Weight of S4PE (liquid detector): 0.9 Lbs. (.4 Kg)
Kit Weight: 13.2 Lbs. (6 Kg)
Kit Dimensions: 18.1 x 7.1 x 4.7 inches (460mm x 380mm
x 170mm)
Storage Temperature: -38.2°F to +160°F
(-39°C to + 71°C)
Rain Proof (model AP2Ce Intrinsically Safe)
Decontaminable body/interchangeable wedging
Shock proof, withstands being dropped from 39.37 in (1
m) high
Export License & End User Restrictions Apply |
AP2C Kit Contents:
(1) AP2C portable detection systems for gas and
liquid agents
(1) S4PE device for sampling liquid agents
(2) Hydrogen storage devices
(2) SAFT Lithium Ion Batteries
(2) S4PE batteries
(1) pack of (10) sample scrapers
(1) pack of (10) test scrapers
(1) buzzer clip
(1) S4PE sampling tube
(1) spare sampling nozzle
(1) Technical Guide
(1) black Pelican
Case for detector & hardware
|
.
| AP2C |
| Symbol |
Name |
Chemical
Name |
Chemical
Formula |
Cas# |
| Vx |
Vx |
O-ethyl-S-(2-iisopropylaminoethyl)
methylphosphonothiolate |
C11-H26-N-O2-P-S |
50782-69-9 |
| Ve |
Ve |
O-Ethyl-S-[2-(diethylamino)ethyl]
ethylphosphonothioate |
C10-H24-N-O2-P-S |
21738-25-0 |
| Vg(Vm) |
Amiton |
O,O-Diethyl-S-[2-(diethylamino)ethyl]
phosphorothioate |
C10-H24-N-O3-P-S |
78-53-5 |
| GA |
Tabun |
Dimethylphosphoramidocyanidic
acid, ethyl esthe |
C5-H11-N2-O2-P |
71-81-6 |
| GB |
Sarin |
Methylphosphofluoridic
acid, 1-methylethyl ester |
C4-H10-F-O2-P |
107-44-8 |
| GD |
Soman |
Methylphosphonofluoric
acid, 1,2,2-trimethylpropyl esther |
C7-H16-F-O2-P |
96-64-0 |
| GF |
Cyclosarin |
Cyclohexyl
methylphosphonofluoridate |
C7-H14-F-O2-P |
329-99-7 |
| GE |
. |
Phosphonofluoridic
acid, ethyl-, isopropyl ester |
C5-H12-F-O2-P |
1189-87-3 |
| HD |
Distilled
Mustard |
Nearly pure
Mustard |
C4-H8-Cl2-S |
505-60-2 |
| H |
Sulfur Mustard |
2,2'-Dichlorodiethyl
sulfide ( 20-30% Sulfur Impurities) |
C4-H8-Cl2-S |
505-60-2 |
| HT |
Sulfur Mustard |
60% HD 40%
T agent to lower freezing point |
C8-H16-Cl2-O-S2.
C4-H8-Cl2-S |
172672-28-5 |
 |
Not suitable
for use to detect Toxic Industrial Materials, Gases & Vapors
(See TIMs
Detector) |
|
|